01-Mar-2018

Maintenance
Monthly maintenance in itself showed no problems. Mail was as usual:

PMAS statistics for February
Total messages    :   2456 = 100.0 o/o
DNS Blacklisted   :      0 =    .0 o/o (Files:  0)
Relay attempts    :   1280 =  52.1 o/o (Files: 28)
Accepted by PMAS  :   1176 =  47.8 o/o (Files: 28)
  Handled by explicit rule
         Rejected :    842 =  71.5 o/o (processed),  34.2 o/o (all)
         Accepted :    116 =   9.8 o/o (processed),   4.7 o/o (all)
  Handled by content
        Discarded :    161 =  13.6 o/o (processed),   6.5 o/o (all)
     Quarantained :     49 =   4.1 o/o (processed),   1.9 o/o (all)
        Delivered :      8 =    .6 o/o (processed),    .3 o/o (all)

but there has been something strange in the antirelay logfiles: between 10-Fen and today, these are a mixture of PMAS.log content and PMAS_ANTIRELAY.LOG. All files were therefore over 60 blocks in size. Searching through these files for the antirelay status (571) held just two files that actually required inspection: the ones of 11th and 25th:

11-FEB-2018 between 21:24:54.19 and 21:28:00.87, from address 23.254.211.233 (190 entries)
25-FEB-2018 between 20:29:42.78 and 25-FEB-2018, from address 23.254.203.20 (146 entries).

In both cases, used a bogus user from this domain, trying to relay to locotrones1029@gmail.com. Once again, hosted by Hostwinds.com; so I’ll warn them again.

Last Itanium system into cluster
The two ‘big’ servers (IRIS and INDRA) are added to the cluster already, but one (INGE) was still to do.
Other than I initially thought, these two big servers have two single-core processors, without hyperthreading. Being similar in hardware (and from the same supplier), it looks these are the older ones of the three. That only CPU #1 is added to the set of CPU’s, is therefore obvious.
INGE, once booted, shows that CPU’s #1, 2 and 3 are added, so it is a newer one. However, it is the one causing problems. I had the machine running when I added the other systems but I couldn’t do that one because before, there as an issue with the SCSI controller so the machine didn’t boot when the system disk was in slot 0 (PUN0, LUN 0) – where is was when I installed VMS on it. Moved it to slot # 2 (PUN2, LUN 0) where I could boot is when accessing EFI and started it by accessing this disk directly and start FSO:\EFI\VMS\VMS_LOADER). But on the EFI boor menu, it was still residing on PUN0 LUN0. So I need to do it interactively.

However, trying to access the ILO yesterday failed: The ILO was non-responsive to PING, TELNET and HTTP on the designated address. So today it was a matter of finding out the cause. Thinking it might be the battery failing (though the supplier said he replaced it) so I took the IKO out, put in a new battery, and re-installed it. Since DHCP is enabled by default, I could figure out what address it would have – but on DIANA, $ DHCPDBDUMP didn’t show any address that did work. $ TCPIP SHO HOST gave me a hint – since the name of the management port is MP<macaddress> now I could access MP, set the configuration to what it should be, and work from there.: Booted the machine from bay#2 – and that worked. Next, shutdown the machine to find out what message was given if the disk was in slot#0 – where it should be. This time, there was nothing wrong; perhaps because when the ILO was out, I could check the connector, may have moved it a bit… SO I added the machine to the cluster. Now being able to access the disk containing the new licenses, this machine is set to work until 12-Mar-2019 – like all others.
Hopefully, this wail keep working – fingers crossed.
Next stage is setting this machine up (as well as INDRA) as DIANA and IRIS, and a quorum node on a laptop running a 64-bit version of Windows (so not the current one).

Fan bearings gone
The main fan of the DS10 server (DIANA) is getting very loud – sounds the bearings are gone. A new one has been ordered but it is uncertain when it will arrive….